Hyundai Sonata: Purge Control Solenoid Valve (PCSV). Description and Operation
Description
Purge Control Solenoid Valve (PCSV) is installed on the surge tank and
controls the passage between the canister and the intake manifold. It is a solenoid
valve and is open when the ECM grounds the valve control line. When the passage
is open (PCSV ON), fuel vapor stored in the canister is transferred to the intake
manifold.
Injector. Repair procedures
Inspection 1. Turn the ignition switch OFF. 2. Disconnect the injector connector. 3. Measure resistance betwee ...Purge Control Solenoid Valve (PCSV). Specifications
Specification Item Specification Coil Resistance (Ω) 19.0 ~ 22.0 [20°C(68°F)] ...See also:
Components and Components Location - Revised
Components
1. Sub frame
2. Lower arm
3. Front disc
4. Drive shaft
5. Steering gearbox
6. Front stabilizer bar
7. Front strut assembly
...
Windshield defrosting and defogging
WARNING - Windshield heating
Do not use the or
position during cooling operation
in extremely humid weather. The difference between the temperature of the outside
air and that of the windshiel ...
Emission control system
The emission control system of your vehicle is covered by a written limited warranty.
Please see the warranty information contained in the Owner’s Handbook & Warranty
Information booklet in ...