Hyundai Sonata: Purge Control Solenoid Valve (PCSV). Description and Operation
Description
Purge Control Solenoid Valve (PCSV) is installed on the surge tank and
controls the passage between the canister and the intake manifold. It is a solenoid
valve and is open when the ECM grounds the valve control line. When the passage
is open (PCSV ON), fuel vapor stored in the canister is transferred to the intake
manifold.
Injector. Repair procedures
Inspection 1. Turn the ignition switch OFF. 2. Disconnect the injector connector. 3. Measure resistance betwee ...Purge Control Solenoid Valve (PCSV). Specifications
Specification Item Specification Coil Resistance (Ω) 19.0 ~ 22.0 [20°C(68°F)] ...See also:
Turn by Turn
The Turn by Turn feature can be used through Blue Link.
1. Direction Indicator Image
2. Remaining distance until next point
3. The Count bar is divided into a total of 9 levels.
4. Current Str ...
TPMS Sensor. Description and Operation
Description
1.
Mode
(1)
Configuration State
A.
All sensors should be in the Low Line (Base ...
Fuel Pump. Repair procedures
Removal
1.
Release the residual pressure in fuel line (Refer to “Release
Residual Pressure in Fuel Line” in this group).
2.
Remove th ...