Hyundai Sonata: Purge Control Solenoid Valve (PCSV). Schematic Diagrams
Circuit Diagram
Purge Control Solenoid Valve (PCSV). Specifications
Specification Item Specification Coil Resistance (Ω) 19.0 ~ 22.0 [20°C(68°F)] ...Purge Control Solenoid Valve (PCSV). Repair procedures
Inspection 1. Turn the ignition switch OFF. 2. Disconnect the PCSV connector. 3. Measure resistance between th ...See also:
Components and Components Location
Components Location
1. PCV Valve
2. Canister
3. Purge Control Solenoid Valve (PCSV)
4. Fuel Tank Pressure Sensor (FTPS)
5. Canister Close Valve (CCV)
6. Fuel ...
Front Wiper Motor. Components and Components Location
Component Location
1. Cap
2. Nut
3. Wiper arm & blade
4. Rivet
5. Cowl top cover
6. Bolt
7. Wiper motor & linkage assembly
...
Fuel Tank Air Filter. Repair procedures
Removal
1.
Turn the ignition switch OFF and disconnect the battery negative
(-) cable.
2.
Disconnect the canister close valve connector (A ...